Petroleum Terminal Handling and Diesel Exhaust Fluid

7 ACO CARTRIDGE SELECTION TABLE Model Number Micron Ratings Inside DIA (in) Outside DIA (in) Length (in) Collapse Pressure (psi) Max. Flow Rate (USGPM) Interchange Information ACO-21001P 0.5 1 1⁄32 2 5⁄8 9 3⁄4 60 15 Fits VF-31E Housing ACO-31001P 0.5 1 5⁄16 3 9 3⁄4 75 20 Fits Purolator Vessel PR-172-3 ACO-40501SPP 0.5 1-12NF 3 3⁄4 5 1⁄2 60 10 Use with head SPH-2 ACO-40801P 0.5 1 3⁄4 4 8 100 13 Rellumit Replacement ACO-40901SPP 0.5 1 3⁄8 -12NF 3 3⁄4 8 1⁄2 60 15 Use with head SPH-3 ACO-41201P 0.5 1 3⁄4 4 12 1⁄4 100 20 Replaces Facet C-707; Purolator Vessel PAG-50 ACO-41601P 0.5 1 3⁄4 4 15 13⁄16 100 27 Rellumit Replacement ACO-41801P 0.5 1 3⁄4 4 18 100 30 Replaces Facet C-706 and Keene BP-419, BP-518 ACO-41901P 0.5 1 3⁄4 4 19 7⁄8 175 32 Rellumit Replacement ACO-51201P 0.5 1 7⁄8 5 5⁄8 12 1⁄4 75 50 Fits VF-61 Housing ACO-512P3P 0.3 1 7⁄8 5 5⁄8 12 1⁄4 75 50 Fits VF-61 Housing ACO-60801P 0.5 3 1⁄2 6 8 1⁄4 100 30 Omeco 6” x 8” Replacement ACO-60901P 0.5 1 1⁄2 6 9 11⁄16 100 36 Fits Fram/Facet VFCS-21 (Element CC-21-7); VF-609 ACO-609P3P 0.3 1 1⁄2 6 9 9⁄16 100 36 Fits Fram/Facet VFCS-21 (Element CC-21-7); VF-609 ACO-61201P 0.5 1 1⁄2 6 13 3⁄4 100 48 Fits Fram/Facet VFCS-22 (Element CC-22-7) ACO-61401P 0.5 3 1⁄2 6 14 1⁄2 175 58 Qualified to EI 1583 6th Edition ACO-62201PTB 0.5 3 1⁄2 6 22 175 88 Qualified to EI 1583 6th Edition ACO-62901P 0.5 3 1⁄2 6 28 3⁄4 175 115 Qualified to EI 1583 6th Edition ACO-63301P 0.5 3 1⁄2 6 33 1⁄4 175 133 Qualified to EI 1583 6th Edition ACO-64401P 0.5 3 1⁄2 6 43 1⁄4 175 173 Qualified to EI 1583 6th Edition ACO-64401PTB 0.5 3 1⁄2 6 44 175 176 Qualified to EI 1583 6th Edition ACO-71801P 0.5 2 1⁄2 6 1⁄4 18 75 65 Fits VF-71E Housing NOTE: 1/2 micron rated Aquacon® Cartridges are recommended for use with jet fuel and avgas. Effluent fuel quality meets requirements for EI 1583 6th Edition. CAUTION: DO NOT USE WITH PRE-MIXED FUELS CONTAINING ANTI-ICING ADDITIVES (FSII) TECHNICAL INFORMATION 1. Max. operating temp.: 160°F (71.1°C) 2. Micron ratings are nominal at 98%+ efficiency 3. AquaconCartridges can significantly reduce flow when loaded with water or dirt. Appropriate precautions should be taken in applications where fuel flowmust be maintained or where surge conditions can occur. 4. Replace the cartridge if the differential pressure exceeds 25 psid. For service life information, please refer to Operating Procedure #1839 or consult your company fuel handling procedures. 5. Typical water holding capacity for ACO-61401P is 700-800 ml.

RkJQdWJsaXNoZXIy NDE1MjE4