NEE Propane & Natural Gas Equipment Catalogue

NATIONAL TOLL FREE DIRECTORY1-866-574-5100 | ON THE WEBwww.nee.ca OUTDOOR LEISURE PRODUCTS POOL & SPA HEATERS Parts and Accessories Selecting the Correct Size H-Series Heater-- For your Swimming Pool Determine your pool’s surface area in square feet: Area - (A+B) x L x .45 Area - R x R x 3.14 Area - L x W Locate in the table above, the surface area equal to or just greater than the pool’s surface area, read to the left and select the appropriate H-Series model. For indoor pool installations, divide the pool’s surface area by 3. Recommended H -Series Model --- Table is based on a 30ºF temperature rise, 3 1/2 MPH average wind velocity and elevation of up to 2,000 feet above sea level. Above Ground Pools- (Temperature Rise in 8 Hours) Spas – (Temperature Rise in 1 Hour) Pool Size Gallons Avg. Temp Rise (ºF) Spa Size Avg. Temp Rise (ºF) 15’ Round 5, 300 15.2º 350 Gallon 28º 18’ Round 7, 600 10.4º 400 Gallon 25º 12’ x 24’ Rectangle 8, 600 9.6º 500 Gallon 20º 21’ Round 10,000 8.0º 700 Gallon 14º 24’ Round 13, 500 5.6º 1,000 Gallon 10º 27’ Round 17,000 4.8º The new H Series heater is also ideal for spa applications. See chart above for approx. temperature rise info. over a 1 hour period. Basic Installations: • 100 lb Propane Cylinder, Capacity : 23 1/2 gal. of propane, Approx. Running Time *: 15 hours, Advantage : Convenience • This size cylinder is delivered to your home and the empty tank is removed. • Must have minimum of 7 gallons of liquid propane in tank to run the heater at 60ºF. That’s why the running time is 15 hours and not 21 (Capacity of tank – 7 gallons/1.1 = Approx. running time). Deluxe Installations: 420 Lbs Tank (4x More capacity than the 100 lbs tank), Capacity : 80 gallons of propane, Approx. Running Time : 103 hours, Advantage : Peace of mind (should one last the entire season). There are additional size tanks available. Consult NEE for information. NEE # Description CHXPRS1931 Pressure Switch CHXGEN1930 Pilot Generator CHXMSI1930 Manual Starter IG CHXPSA1930 Pressure Switch Adapter HAXBRN1930 Main Burner (for H Series) UHXNEGVT1150 Vent Hood Negative (Vertical H150FD) UHXNEGVT1200 Vent Hood Negative (Vertical H200FD) UHXNEGVT1251 Vent Hood Negative (Vertical H250FD) UHXNEGVT1300 Vent Hood Negative (Vertical H300FD) UHXNEGVT1350 Vent Hood Negative (Vertical H350FD) UHXNEGVT1400 Vent Hood Negative (Vertical H400FD) UHXPOSHZ1150 Vent Hood Positive (Horizontal H150FD) UHXPOSHZ1200 Vent Hood Positive (Horizontal H200FD) UHXPOSHZ1250 Vent Hood Positive (Horizontal H250FD) UHXPOSHZ1300 Vent Hood Positive (Horizontal H300FD) UHXPOSHZ1350 Vent Hood Positive (Horizontal H350FD) UHXPOSHZ1400 Vent Hood Positive (Horizontal H400FD) CHXRLV1930 Relief Valve CHXTST1930 Thermostat without Knob CHXTSW1930 On/Off Switch NEE # Description CZXPRS1105 Water Pressure Switch HAXFCT1930 Flow Control Thermostat HAXFHD1931 Front Header Only HAXCPA1932 Control Panel Bezel Assembly HAXHXA1253 Heat Exchanger Assembly - H250 HAXIGN1931 Ignitor/Bracket Assembly HAXTLK1930 Temperature Limit Kit HAXTST1930 Thermostat with Knob HAXWHA0001 MilliVolt Wiring Harness HAXWHA0002 HAXHXA1153 Heat Exchanger Assembly - H150 HAXHXA1303 Heat Exchanger Assembly - H300 HAXHXA1353 Heat Exchanger Assembly - H350 HAXHXA1403 Heat Exchanger Assembly - H400 HMXHLI2932 Immersion Hi-Limit Front (Rear- 160°) IDXBNR1930 Burner/Specify LP Or NG IDXIGN1930 Ignitor (for H1001DP1) IDXMOD1930 Ignition Module IDXTST1930 Thermostat

RkJQdWJsaXNoZXIy NDE1MjE4