Retail Petroleum Equipment

FLUID INVENTORY CONTROL | PUMP SENTINEL 88 FEATURES Prevents fluid spills during non-working hours by using a built in timer to turn off air supply to all pumps at a predetermined time each day Allows for controlled dispensing of fluids Capable of preventing fluid theft by using switches to enable or disable up to six pumps Master key needed to turn system on Ideally suited to improve existing FIC systems that have been installed without the protection of air solenoids 6’ cable to run to junction box Small Console footprint: 6.5" L x 5" W x 3" H Patent applied for • • • • • • • • Power Required. . . . . . . . . . . . . . . 120 VAC, 60/50 Hz, 50 Watts Control Capacity . . . . . . . . . . . . . 6 Products Operating Temperature . . . . . . . . 0 °F -140 °F (-17 °C - 60 °C) Solenoid Rating . . . . . . . . . . . . . . . 24 VDC, 5 Watts Max. Dimensions . . . . . . . . . . . . . . . . . . . 3” H x 6.5” W x 5” D Cable Length. . . . . . . . . . . . . . . . . 6 feet Air Solenoid . . . . . . . . . . . . . . . . . . 3120-033 (sold separately) Provides for the remote shutdown of dispensing pumps from the pump sentinel. Pressure rating 200 PSI; port thread size ⅜” NPT(F); 24 Volt DC power. Order one per controlled pump. No. 18 AWG wire is recommended for all runs less than 400 feet. For runs from 400 to 625 feet, use wire no. 16 AWG or larger. Normally the 24 VAC wiring can be run around the overhead structure of the building without using conduit. 3110-009 Pump Sentinel Console MODEL AVAILABLE SYSTEM SPECIFICATIONS Service bulletin SB3048

RkJQdWJsaXNoZXIy NDU1Njc=