Retail Petroleum Equipment

A Secondary Conta i nment Vacuum Sens i ng System for use w i th Veeder- Root’s ATG Systems . The Secondary Conta i nment Vacuum Sens i ng (SCVS) System i s des i gned to detect leaks i n double- walled tanks and p i p i ng systems wh i le help i ng to conta i n a release of product wh i le under vacuum . The system cons i sts of : • Vacuum Sensors, connected to tank, sump or p i p i ng i nterst i ces • A Submers i ble Turb i ne Pump (STP), to prov i de a source of vacuum • A Smart Sensor Interface w i th Embedded Pressure Module i n a TLS-350 Mon i tor i ng System The Vacuum Sensor i s i nterfaced to Veeder- Root's TLS-350 Mon i tor i ng System v i a i ntr i ns i cally safe w i r i ng to prov i de system status, replen i sh rate, alarm, and d i agnost i c i nformat i on . Vacuum Sensor K i ts are ava i lable i n a var i ety of models : • For mon i tor i ng double-walled p i p i ng and sump i nterst i ces • For mon i tor i ng double-walled steel tank i nterst i ces (see back page) • For double-walled f i berglass tanks These k i ts d i ffer i n the number of vacuum sensors and the conf i gurat i on of assoc i ated l i qu i d sensors . An i nl i ne k i t mounted l i qu i d sensor i s used for Vacuum Sensors mon i tor i ng p i p i ng and sumps . An external l i qu i d sensor (to be i nstalled i n the secondary space at the bottom of the tank) i s prov i ded w i th one of the Vacuum Sensors i n the steel and f i berglass tank k i ts to mon i tor the tank . Max i m i ze protect i on w i th a vacuum mon i tored secondary conta i nment system . Operat i ng Temperature Rat i ng: -25 degrees C to +70 degrees C Cable Length: 8 feet Sensor D i mens i ons: 5” high x 5” wide 2” deep Console Capab i l i ty The Vacuum Sensor is compatible with the following consoles: Console TLS-350R/EMC w/BIR* TLS-350 Plus/EMC Enhanced* TLS-350/EMC* *Upgrade Note: The Vacuum Sensor System requires the console to have version 24C software (or greater) along with an ECPU2 or ECPU w/ NVMEM 1 board . For more information call: 1-888-561-7942 Standard Models Veeder-Root P/N Descr i pt i on 330020-467 4 Vacuum Sensor Kit* for steel tank 330020-468,-469,-470,-471 4 Vacuum Sensor Kit* for fiberglass tanks (4',6',8',10') 330020-486 4 Vacuum Sensor Kit* for no tank 330020-472 3 Vacuum Sensor Kit* for steel tank 330020-473,-474,-475,-476 3 Vacuum Sensor Kit* for fiberglass tanks (4',6',8',10') 330020-485 3 Vacuum Sensor Kit* for no tank 330020-479 2 Vacuum Sensor Kit* for steel tank 330020-481,-482,-483,-484 2 Vacuum Sensor Kit* for fiberglass tanks (4',6',8',10') 330020-480 2 Vacuum Sensor Kit* for no tank 330020-495 1 Vacuum Sensor Kit* for no tank 857280-100 Vacuum Sensor for piping & sumps 857280-200 Vacuum Sensor for steel tanks 857280-301,- 302,-303,-304 Vacuum Sensor for fiberglass tanks (4’,6’,8’,10’) 330020-448 Mounting Kit 332217-001 Relief Valve Assembly 332250-001 Smart Sensor w/Embedded Pressure Sensor Module (7 Channel)** Secondary Conta i nment Vacuum Sens i ng System * Kits include mounting bracket, 6' of vacuum hose, relief valve assembly (if required) and the appropriate number of liquid sensors, 3-way ball valves, barbed fittings and hose clamps so that each vacuum sensor can monitor a single tank, sump or piping interstices . ** The Vacuum Sensing System requires one 7 channel Smart Sensor Interface with Embedded Pressure Module, 8 channel Smart Sensor Modules (p/n 329356-004) can be used for Vacuum Sensors eight and above . Features and Benef i ts Satisfy Requirements • Cert i f i ed to meet Cal i forn i a's requ i rement for secondary space mon i tor i ng for tanks and l i nes as requ i red by AB 2481 • Sat i sf i es the requ i rements for Class I Leak Detect i on as def i ned by the European Standard EN 13160-2 • 3rd Party, Nat i onal Work Group and LG113 l i sted Reduce Exposure to Risk • Alarms when vacuum cannot be ma i nta i ned or when replen i sh rate exceeds 85 l i ters per hour • The system alarms when l i qu i d i s detected i n the secondary space • Fac i l i tates per i od i c operab i l i ty test i ng Leverage Existing Veeder-Root Systems • Uses STP as the vacuum source and works w i th Red Jacket and FE STPs • Installs i n the STP sump and connects to the console v i a i ntr i ns i cally safe w i r i ng • Able to share w i r i ng condu i t w i th other Veeder-Root i ntr i ns i cally safe (IS) probes and sensors i nclud i ng sump or l i ne leak sensors • Interfaces to the Smart Sensor Interface w i th Embedded Pressure Module • Prov i des for pos i t i ve shut down of pressur i zed l i nes when requ i red • S i mple i nstallat i on, no need to mess w i th br i ne Accessor i es Part Descr i pt i on Quant i ty/Length Part Number 1/4” NPT Barbed Fittings 3 330020-487 1/4” NPT Barbed Fittings 15 330020-488 1/4” NPT Barbed Fittings 25 330020-489 Barbed Tee 1 576008-657 Vacuum Hose 25’ 25’ 332310-001 Vacuum Hose 50’ 50’ 332310-002 Vacuum Hose 100’ 100’ 332310-003 3–Way Ball Valve 1 576008-649 Schrader Valve Barbed Fitting 3 330020-496 Schrader Valve Barbed Fitting 15 330020-497

RkJQdWJsaXNoZXIy NDU1Njc=