Petroleum Terminal Handling and Diesel Exhaust Fluid

EATONAerospace Group TF100-104E May 2013 5 PART NUMBER DESCRIPTION QTY COMMENTS 64235 Digital II Control System 1 — 64236 Hand-Held Calibration Unit, complete with cables 1 Only one calibration unit is required per airport for this type of system 64101 Transducer for test rig 1 Required for setting up and calibration 64108 Vehicle Transducer 1 To be mounted on vehicle 64802 or 64804 Hydrant Coupler. Model 64804 has excess flow capability 1 See separate catalog sheet (TF100-125 or TF100-114) for detail information 64237 or 64338 Remote Display (optional) 1 Model 64237 is LCD type and Model 64338 is LED type remote display. This is to be used for mounting at a remote location such as a deck. 767181 327 Veeder Root pulser 1 Mounting kit part number 0370020 009 may be required. Any brand pulser that produces pulses from 10-100 pulses per gallon/liter can be used; however, if one that produces less than 100 pulses is used, the unit will have to be calibrated. Dual Digital II system for hydrant servicers —The following parts must be ordered to complete a system. Note: The required pulser is not manufactured by Eaton and must be ordered from another supplier (Veeder Root or other — see below). Single Digital II System for Hydrant Servicers —The following parts must be ordered to complete a system. Note: The required pulser is not manufactured by Eaton and must be ordered from another supplier (Veeder Root or other — see below). PART NUMBER DESCRIPTION QTY COMMENTS 64235 Digital II Control System 2 — 64236 Hand-Held Calibration Unit, complete with cables 2 Only one calibration unit is required per airport for this type of system 64101 Transducer for test rig 2 Required for setting up and calibration 64108 Vehicle Transducer 2 To be mounted on vehicle 64802 or 64804 Hydrant Coupler. Model 64804 has excess flow capability 1 See separate catalog sheet (TF100-125 or TF100-114) for detail information 64504 or 64514 3 or 4-inch Inline Control Valve as appropriate 1 Model 64504 — 3-inch. Model 64514 — 4-inch. See separate catalog sheet (TF100-112) for detail information. 64237 or 64338 Remote Display (optional) 1 Model 64237 is LCD type and Model 64338 is LED-type remote display. This is to be used for mounting at a remote location such as a deck. 64337 Switchable Remote Display (optional) 1 Model 64337 is a remote display that can be used as the primary display with the two control systems mounted out of sight of the operator. A separate Model 64338 would be used as the other display. 767181 327 Veeder Root pulser 1 Mounting kit part number 0370020 009 may be required. Any brand pulser that produces pulses from 10-100 pulses per gallon/liter can be used; however, if one that produces less than 100 pulses is used, the unit will have to be calibrated. Other Items Not Furnished by Eaton There are several items uniquely required in the Digital II System that are not furnished by Eaton. In addition to the meter pulser, the accumulator system used on servicers is furnished by the customer. This system consists of an accumulator with a usable volume of at least one gallon (4 liters), a ¼-inch check valve and a dry break disconnect as shown in the hydrant servicer system figure on page 6. This system is used to provide stored power to get the coupler to open upon activating the deadman at the beginning of each refueling. It must be initially charged to a minimum of 60 psi (4.137 bar) after the building of the vehicle and after the system has been removed for service and depressurized for any reason. Once the initial charging has been achieved, the hydrant system will keep the accumulator system charged. A larger accumulator may be required should the hydrant system pressure be less than 90 psi (6.205 bar) at any time during a refueling. Ordering Data

RkJQdWJsaXNoZXIy NDE1MjE4