Petroleum Terminal Handling and Diesel Exhaust Fluid

TLM Values vs. PD Meter Lower Pressure drop Lower Costs Lower Weight Lower Maintenance Identical Size Same or better Accuracy Specifications Safety 02 48 69 70 80 This document is not contractual, Faure Herman keeps the right to modify certain characteristics without notice. 1600 A 03/05 Key Technological Features • Weight & space savings • No upstream & downstream straight length needed • Supports reverse flow • Single K-factor for 2 liquids • Integrated flow conditioner Key Customer Advantages • Low cost of ownership • Easy installation • Long-term reliability and stability • Accurate measurement • Compatible with a wide range of electronics A Compact Metering Solution Environment Process temperature range Climatic protection - 40 to +180 °C (- 40 to + 292 °F) IP 65 EEx ia version (with coil &/or preamp) EEx d ia version (with coil &/or preamp) Compatible with installation in Zones 1 & 2 Group II 1G Compatible with installation in Zones 1 & 2 Group II 2G Refer to the table, Stainless steel Weld Neck ANSI 150/300 Titanium or Aluminium Cable-gland 3/4” NPT ± 0.15 % of reading value on 1 product ± 0.25 % of reading value on 2 products Better than ± 0.02 % on all products 10 : 1 viscosity < 15 cSt Available Available Electrical options Pick-up coil Pick-up coil + preamp. * * FH71 open-collector preamp. Performances Accuracy Repeatability Turndown ratio Mechanical Meter size Meter body material Flange material Impeller Connections TLM HELIFLUtM 0 500 1000 1 500 2 000 2 500 3 000 l/min 0 50 100 150 200 m /h 0 150 300 450 600 750 900 GPM 0,50 0,25 0,00 -0,25 -0,50 - ERROR ( %) + 3 0 1000 2 000 3000 4000 5000 6000 l/min 0 100 200 300 400 m /h 0 250 500 750 1000 1 250 1 500 GPM 0,50 0,25 0,00 -0,25 -0,50 ERROR ( %) + 0.6 cSt 6 cSt 3 3-30 130 000 24 49.2 3 50 13 11 30 500 132 110 25 470 18.5 200 13 000 8.5 49.2 5 83 22 18 50 833 220 180 25 470 18.5 480 22 500 13 85.2 7 116 30 44 70 1 166 308 440 27 470 18.5 200 13 000 13 49.2 11 183 48 40 110 1 833 484 400 27 470 18.5 500 13 000 13 49.2 15 250 66 55 150 2 500 660 550 27 470 18.5 900 13 000 13 49.2 7 116 30 25 70 1 166 308 250 37.5 508 20 200 13 000 13 49.2 11 183 48 40 110 1 833 484 400 37.5 508 20 410 13 000 13 49.2 15 250 66 55 150 2 500 660 550 37.5 508 20 780 4 400 3.6 16.7 20 333 88 25 200 3 333 880 250 32 508 20 550 3 600 3.6 13.6 30 500 132 30 300 5 000 1 321 300 32 508 20 1 200 3-50 3-70 3-110 3-150 4-70 4-110 4-150 4-200 4-300 K-factor (p/m3) K-factor (p/l) K-factor (p/GPM) Min. linear flowrate (m3/ h) Min. linear flowrate (l/m) Min. linear flowrate (GPM) Min. linear frequency (Hz) Max. linear flowrate (m3/ h) Max. linear flowrate (l/mn) Max. linear flowrate (GPM) Max. linear frequency (Hz) Weight Length flange to flange (mm) Length flange to flange Pressure drop (mbar) Single Product Calibration Multi-viscosities FAURE HERMAN METER Inc. - Houston TX. 77056 (U.S.A.) Phone : + 1713 623 0808 - Fax : + 1713 623 2332 - E-mail : [email protected] FAURE HERMAN - Route de Bonnétable - B.P. 20154 - 72406 La Ferté-Bernard Tél.: + 33 (0)2 43 60 28 60 - Fax : +33 (0)2 43 60 28 70 - http://www.faureherman.com FAURE HERMAN - 5, avenue des Andes - B.P. 126 Les Ulis - 91944 Courtabœuf Cedex - France Tél. : + 33 (0)1 69 82 77 00 - Fax : + 33 (0)1 69 86 18 40 E-mail : [email protected]

RkJQdWJsaXNoZXIy NDE1MjE4