5 Two control buttons provide access to: • Delivery quantity ----------------------- • Flowrate ------------------------------- • Product temperature------------------- • Time of day ---------------------------- • Setting preset deliveries --------------- • 10 digit totalizer ----------------------- • Single point calibration ---------------- • Selection of four different products---- As a stand alone device, the LCR-II selector switch is used for “Pump & Print” operations. The control buttons provide access to additional device functions, as shown to the right. “ Pump & Print” operation Advanced software features The LectroCount LCR-II can be configured to address the specific needs of the application. A few of the special features resident in the LectroCount LCR-II are: • Multi-point calibration. When the meter is being commissioned in the field, the Lap Pad can be used to calibrate meter performance for either single point or multi-point calibration at up to 10 flow rates from low flow to high flow. • Inventory monitoring. The LCR-II can be set up to monitor the remaining volume (current inventory) in the delivery vehicle. Simply select INVENTORY for the preset type. • Low flow alarm. Auxiliary output 1 can be set to MONITOR FLOWRATE. When set to MONITOR FLOWRATE, the LCR-II will activate a circuit at the beginning of each delivery. If the flowrate does not exceed 40 GPM during the delivery, the output remains active. This can be used to control an external device, such as an alert light and to print a special note on the delivery ticket. This may be an indication that the system filter/strainer requires maintenance.