3 Pulse Output Device (POD) M & MA Series Meters Pulses/ Gallon/ Channel Pulses/ Liter/ Channel Max Output kHz MA-4 407.9 107.8 0.27 M-5, MA-5 (3:1) 407.99 107.8 0.41 M-5, MA-5 (1:1) 1,223.7 323.4 1.22 M-7, MA-7 555.5 146.8 0.93 M-10 555.5 146.8 1.48 M-15, MA-15 205.8 54.4 0.69 M-25 205.8 54.4 0.86 M-30 74.2 19.6 0.43 M-40 74.2 19.6 0.53 M-60 (new style) 39.8 10.5 0.40 M-60 (old style) 25.5 6.7 0.26 M-80 39.8 10.5 0.53 MS Series Meters Pulses/ Gallon/ Channel Pulses/ Liter/ Channel Max Output kHz MS-7 555.5 146.8 0.93 MS-15 205.8 54.4 0.69 MS-25 205.8 54.4 0.86 MS-30 74.2 19.6 0.43 MS-40 74.2 19.6 0.53 MS-75 25.5 6.7 0.30 MS-120 15.8 4.2 0.26 NOTE: Dimensions shown are not for construction use. Consult factory when certified Engineering Drawings are required. The diagram shows the voltage output for a clockwise rotation of the POD with Channel A leading Channel B. For reverse flow ( counterclockwise) applications, Channel B leads Channel A. Signal Output Schematic