Typical pipe dimensions and weights Nominal Pipe Nominal Wall Average Pipe Pipe Size ID Thickness1 Sectional Area2 Weight ( in) (mm) ( in) (mm) ( in) ( mm) ( in2) ( mm2) ( lb/ft) (kg/m) 1 25 1.07 27 .140 3.6 0.50 323 0.4 0.6 11⁄2 40 1.67 42 .140 3.6 0.80 516 0.7 1.0 23 50 2.10 53 .123 3.7 .73 730 0.7 1.3 33 80 3.21 82 .126 3.7 1.07 1100 1.1 1.8 43 100 4.14 105 .151 3.8 1.78 1760 1.7 3.0 63 150 6.19 159 .181 4.6 3.22 2620 2.6 4.5 8 200 8.22 209 .226 5.7 5.83 3760 4.3 6.4 10 250 10.35 263 .226 5.7 7.31 4720 5.4 8.0 12 300 12.35 314 .226 5.7 8.69 5610 6.4 9.5 14 350 13.56 344 .250 6.4 10.32 6660 7.4 11.0 16 400 15.50 394 .269 6.8 13.33 8600 9.5 14.1 1) Minimumwall thickness shall not be less than 87.5%of nominal wall thickness in accordance with ASTMD2996. 2) Use these values for calculating longitudinal thrust. 3) No-shave pipe. Typical pipe performance Nominal Internal Collapse Pipe Size Pressure Rating1 Pressure Rating2 Designation ( in) (mm) ( psig) (MPa) ( psig) (MPa) ( per ASTM D2996) 1 25 450 3.10 945 6.52 RTRP-11FE-1112 11⁄2 40 450 3.10 280 1.93 RTRP-11FE-1114 23 50 450 3.10 260 1.80 11 FW-2232 33 80 450 3.10 80 0.55 11 FW-2232 43 100 450 3.10 70 0.48 11 FW-2232 63 150 375 2.59 50 0.34 11 FW-2232 8 200 250 1.72 30 0.21 RTRP-11FE-1114 10 250 200 1.38 14 0.097 RTRP-11FE-1114 12 300 170 1.17 8 0.055 RTRP-11FE-1114 14 350 165 1.14 8 0.055 RTRP-11FE-1115 16 400 165 1.14 8 0.055 RTRP-11FE-1116 1) At 200°F (94°C) using Bondstrand type PSX™•34 adhesive. For sustained service above 200°F, reduce ratings linearly to 50% from 200°F to 250°F (121°C). 2) At 70°F (21°C). Reduce linearly to 90%at 150°F (66°C), 80%at 200°F (94°C), and 65%at 230°F (110°C). 3) No-shave pipe. 3