Composites P.O. Box 71370 11 McBride Street Newnan, Georgia 30263 Tel: (770) 253-2000 Fax: (770) 253-9234 FIBERGLASS- COMPOSITEPIPEGROUP- HEADQUARTERS P.O. Box 801148 • Houston, TX 77280 • Tel: (713) 690-7777 • Fax: (713) 690-2842 • http://www.ameron.com Europe Ameron B.V. J.F. Kennedylaan 7 4191 MZ Geldermalsen The Netherlands Tel: +31 345 587 587 Fax: +31 345 587 561 [email protected] Americas P.O. Box 878 Burkburnett, TX 76354 Tel: (940) 569-1471 Fax: (940) 569-2764 Centron International P.O. Box 490 600 FM 1195 South Mineral Wells, Texas 76068 Tel: (940) 325-1341 Fax: (940) 325-9681 http://www.centrongre.com Asia Ameron (Pte) Ltd. No. 7A, Tuas Avenue 3 Singapore 639407 Tel: 65 861 6118 Fax: 65 862 1302/861 7834 [email protected] Important Notice This literature and the information and recommendations it contains are based on data reasonably believed to be reliable. However, such factors as variations in environment, application or installation, changes in operating procedures, or extrapolation of data may cause different results. Ameron makes no representation or warranty, express or implied, including warranties of merchantability or fitness for purpose, as to the accuracy, adequacy or completeness of the recommendations or information contained herein. Ameron assumes no liability whatsoever in connection with this literature or the information or recommendations it contains. Product specifications are subject to change. Recommended maximum support spacing for Bondstrand Series 7000 pipe at various operating temperatures. Values based on 0.5-inch (12 mm) deflection at midspan for fluid specific gravity = 1.0. Nominal Span in Feet (m)* Pipe Size Temperature in °F (°C) ( in) (mm) 100 (38) 150 (66) 200 (93) 2 50 11.8 3.6 11.2 3.4 10.4 3.2 3 80 13.6 4.1 12.8 3.9 11.9 3.6 4 100 15.4 4.7 14.6 4.5 13.6 4.1 6 150 17.2 5.2 16.4 5.0 15.1 4.6 8 200 19.2 5.9 18.1 5.5 16.9 5.2 10 250 20.3 6.2 19.2 5.9 17.9 5.5 12 300 21.3 6.5 20.1 6.1 18.7 5.7 14 350 22.3 6.8 21.2 6.5 19.6 6.0 16 400 23.3 7.1 22.3 6.8 20.5 6.2 * Span recommendations are intended for normal horizontal piping support arrangements, a compromise between continuous spans and simple spans, but include no provision for weight such as fittings, valves, flanges, etc. or thrust from branches and turns. Fully continuous spans may be installed with support spacing up to 20%greater than values shown for this deflection; for simple spans the support spacing should be reduced by 20% from tabulated values. Support Spacing Written comments regarding this document are invited. Please write Engineering Manager, Ameron Fiberglass Pipe Division. © 1991 Ameron• FP305D (8/00) supersedes FP 305C (1/95) • Printed in U.S.A. • 5M [186] Technical Support Consult Ameron for further recommendations concerning the use of Bondstrand pipe systems. For more information regarding static electricity in fuel pipelines, request Ameron Fiberglass Pipe Division publication EB-43.
RkJQdWJsaXNoZXIy NDE1MjE4