CANADA’S LEADER IN ENERGY PRODUCTS EQUIPMENT WATER HEATERS COMMERCIAL WATER HEATERS AO Smith Masterfit Commercial Gas Tank Type Water Heaters Features: The Eliminator Self-cleaning system High Limit Switch (E.C.O.) Electronic Ignition Control Automatic Flue Damper Device Circulating Pump Heater Performance Efficiency is 80% Standard equipment on these models is a 24V control system including combination thermostat and high limit, automatic electronic ignition, low profile vertical draft hood with integral automatic flue damper, manual service switch, hand hole cleanout(s), T and P relief valve. Requires 15 amp, 120 volt, 1 phase, 60 Hz electrical supply. ASME Construction is standard on models BTRC 200A, 250A, 275A, 400A and 500A. NEE # Capacity BTU Fuel Type Vent Gas Inlet Inlet Connections Outlet Connections Diameter Height Width Weight Recovery Rates (USG) at 100º F BTRC120-P 71 USG 120,000 LP * 5” 1/2” 1 1/2” (top, front, back) 1 1/2” (top, front, back) 27 3/4” 69 3/4” 27 3/4” 400 lbs 116 BTRC154-P 81 USG 154,000 6” 73” 470 lbs 149 BTRC180-P 76 USG 180,000 70 1/2” 174 BTRC197-P 95 USG 197,000 81 1/2” 603 lbs 193 BTRC199-P 76 USG 199,000 70 1/2” 470 lbs BTRC200A-P 100 USG 200,000 1 1/2” (top & back), 2” (front) 1 1/2” (top & back), 2” (front) 30 1/4” 72” 30 1/4” 630 lbs BTRC250A-P 250,000 8” 1 1/2” (top), 2” (front, back) 1 1/2” (top), 2” (front, back) 242 BTRC251-P 65 USG 251,000 1 1/2” (front, back) 1 1/2” (front, back) 27 3/4” 75” 27 3/4” 750 lbs 243 BTRC275A-P 100 USG 275,000 1 1/2” (top) & 2” (front, back) 1 1/2” (top) & 2” (front, back) 72” 630 lbs 267 BTRC305-P 65 USG 305,000 1 1/2” (front, back) 1 1/2” (front, back) 75” 750 lbs 296 BTRC365-P 365,000 3/4” 349 BTRC400A-P 100 USG 399,000 1/2” 1 1/2” (top), 2” (front, back) 1 1/2” (top), 2” (front, back) 30 1/4” 75 1/2” 30 1/4” 760 lbs 388 BTRC500-P 85 USG 500,000 1” 1 1/2” (top, front, back) 1 1/2” (top, front, back) 27 3/4” 81 1/2” 27 3/4” 812 lbs 485 * Replace -P with -NG in part number for natural gas model. AO Smith Cyclone Water Heaters Features: 94% Thermal Efficiency Flexible Venting Advanced Electronic Controls Preset Power burner Submerged Combustion Chamber Zero inch clearance Spiral-wound flue tube Scale-free, glass-lined tank Handhole cleanout Foam insulation Easy installation Seamless glass-lined steel tank construction, in which the glass coating is applied to the water side surfaces of the tank after the tank has been assembled and welded. The condensing flue coil is coated on the flue gas side with acid resistant glass lining. The control is an integrated solid state temperature and ignition device with integral diagnostics, with LED fault display capability and digital temp display, and is foam insulated. NEE # Capacity BTU Fuel Type Inlet NPT Outlet NPT Diameter Height Width Weight Recovery Rates (USG) at 100º F BTH120-N 60 Gallons 125,000 NG 1 1/2” 1 1/2” 27 3/4” 55 1/2” 27 3/4” 350 lbs 138 BTH120-P 120,000 LP BTH150-P 100 Gallons 150,000 75 1/2” 438 lbs 173 BTH199-P 199,000 230
RkJQdWJsaXNoZXIy NDE1MjE4