NATIONAL TOLL FREE DIRECTORY1-866-574-5100 | ON THE WEBwww.nee.ca NEE TO OUR CUSTOMERS With close to 60 years of experience servicing the Energy Industry in Canada, National Energy Equipment Inc. “NEE”, prides itself on delivering the highest quality and best value to you, our Customers. This philosophy has helped us grow into the largest distributor of energy equipment products in Canada. Our goals are accomplished through: • A solid financial foundation. • A broad offering of the best quality products available. • Strong long-term partnerships with key vendors. • Investment in motivated, dedicated and talented people. • A continuous process of improvement and innovation. • A flexible, regionally focused team based approach to business. • A passion to earn your business by exceeding your expectations. • Knowing that every day you, our customers, help us better understand what we can do to make your job easier and your business more profitable. We have developed this equipment catalogue as a service to you, our customers, to provide an easy, quick reference guide when placing your orders. If you have any questions or would like to learn more about what National Energy Equipment has to offer, please feel free to call our branches direct or our national directory at 1-866-574-5100 and visit us at www.nee.ca. Sincerely, National Energy Equipment Inc.

NATIONAL TOLL FREE DIRECTORY1-866-574-5100 | ON THE WEBwww.nee.ca NEE NEE BRAND PARTNERSHIPS

CANADA’S LEADER IN ENERGY PRODUCTS EQUIPMENT NEE TERMS & CONDITIONS PAYMENT TERMS To customers with established credit net 30 days from date of invoice. PRICES All prices are F.O.B. our distribution centre and subject to change without notice, and all quotations are made for immediate acceptance. Minimum order is $25.00 CAN. Federal, Provincial, Municipal taxes are not included. FREIGHT The most economical and dependable routing will be used and shipments will be prepaid and charged unless customer specifies method of transportation at customers expense. Title passes to the buyer upon delivery of the goods to the carrier. National Energy Equipment Inc. (NEE) and affiliated companies are not responsible for merchandise lost or damaged in transit. Customer’s claims for damage, loss, etc., must be filed against the carrier. SHORTAGE CLAIMS Shortage claims must be made within two days after receipt of shipment. WARRANTY Warranties as expressed by individual manufacturers will be honoured. RETURNED MATERIAL No material should be returned without NEE’s prior approval. Transportation charges must be prepaid. A 20%minimum restocking charge may be applied. Merchandise returned must be accompanied by a Returned Material Authorization Number (RMA), which must be provided by contacting NEE Customer Service. While the information contained in this catalogue is presented in good faith and believed to be accurate, NEE or affiliated companies do not guarantee satisfactory results from reliance upon such information. Nothing contained herein is to be construed as a warranty or guarantee, expressed or implied, regarding the performance, merchant ability, fitness or any other matter with respect to the products, nor as a recommendation to use any product or process in conflict with any patent. Original manufactures of products represented by NEE, reserve the right, without notice, to alter or improve the designs or specifications of the products described herein. GENERAL PRODUCT SAFETY WARNINGS See individual product instruction manuals supplied with the product for more detailed information. Contact National Energy Equipment Inc. if you have additional product questions. WARNING: Equipmentmust be installed, operated, andmaintained in accordancewith federal, provincial, and local codes, regulations and equipment instructions. Only personnel trained in the proper procedures, codes, standards, and regulations of the Propane, Natural Gas or Anhydrous Ammonia industries should install and service this equipment. Due to normal wear or damage that may occur from external sources, all equipment must be inspected and maintained periodically. The frequency of inspection and replacement of equipment depends upon the severity of the service conditions or age requirements of local, provincial, federal regulations, and equipment instructions. Do not use any equipment that leaks, fails to work properly, or that has damaged or missing parts. Equipment repair or replacement should be made promptly in order to prevent accidents. Failure to follow these instructions or to properly install and maintain this equipment could result in product leakage, explosion and/or fire causing property damage, personal injury or death.

NATIONAL TOLL FREE DIRECTORY1-866-574-5100 | ON THE WEBwww.nee.ca REGULATORS DOMESTIC REGULATORS First Stage Regulators First stage regulators are typically used to reduce tank pressure to an intermediate pressure; usually 5 to 10 PSI for further pressure reduction by a second stage regulator located closer to the load. This allows for the use of smaller piping and can contribute to substantial savings. Care must be taken in colder climates to ensure that the pressure setting does not create dew point concerns that could cause the propane vapour to condense back to a liquid resulting in regulator freeze-ups and possible problems at the burner. Fisher First Stage Regulators The R622H First Stage Regulator is constructed of corrosion-resistant and wear-resistant materials, designed to provide a recommended replacement life of 20 years (a 30% improvement over previously existing designs). Features: • 1/8” F NPT pressure taps on the inlet and outlet for easy system pressure checks. • Large 3/4” drip-drip lip vent to reduce vent blockage and freeze-ups. • High capacity internal relief with built-in travel stop providing the best over-pressure protection in the industry. • Superior lock-up performance for precise and consistent performance. • Corrosion-resistant materials and coatings for durability. • Positive draining spring case. • 5 Year Warranty. The R122H Non-Adjustable Regulator features a molded diaphragm, over- sized relief valve & a compact design with excellent capacity and performance for a small first stage regulator. NEE # BTU Capacity Inlet Connection Outlet Connection Adjustment Range Factory Setting Vent Location Internal Relief Bracket R622H-JGK 2,250,000 F. POL 3/4” F NPT 4 - 6 PSI 5 PSI 3/4” F NPT Screened and over outlet Yes P100A or P100C R622H-HGK 2,000,000 1/2” F NPT R622H-BGK 1/2” F NPT R622H-JGJ 2,500,000 F. POL 3/4” F NPT 8 - 12 PSI 10 PSI R622H-HGJ 2,100,000 1/2” F NPT R622H-DGJ 2,400,000 3/4” F NPT 3/4” F NPT R622H-BGJ 2,100,000 1/2” F NPT 1/2” F NPT R122H-AAJ 1,100,000 1/4” F NPT Non Adjustable 3/8” F NPT Screened and over outlet P100A R622H R122H

CANADA’S LEADER IN ENERGY PRODUCTS EQUIPMENT 5 REGULATORS DOMESTIC REGULATORS Second Stage Regulators Second stage regulators are used to satisfy the inlet requirements of the appliance and are typically designed to provide propane appliances with a delivery pressure between 9-13” W.C. As the second stage regulator of a 2 stage system, this model works with an inlet pressure usually between 4 to 10 PSI. This allows it to maintain a consistent delivery pressure to the load - regardless of ambient temperatures that affect the pressure of fuel in the storage tank. Line sizing from the outlet of the regulator is critical for proper performance, of which the B149 code book provides tables for. Fisher Second Stage Regulators Constructed of corrosion-resistant and wear-resistant materials, R600 Series Fisher Regulators are designed to provide a recommended replacement life of 20 years (a 30% improvement over previously existing designs). The R622 and 652 Fisher Regulators are designed to exceed the UL requirements of NFPA 58 by ensuring that the outlet pressure will never exceed more than 2 PSI – even in a double failure situation when used with the R622H series first stage regulators. The R622 Regulator offers a straight through design. The R652 Regulator is a 90° configuration with a ¾” back outlet for direct piping through the wall or into a meter set. The R222 Compact First Stage Regulators are built with the same features and benefits as the R622 series, but in a smaller body style. Features: • 1/8” F NPT pressure taps on the inlet and outlet for easy system pressure checks. • Large 3/4” drip-drip lip vent to reduce vent blockage and freeze-ups. • High capacity internal relief with built-in travel stop providing the best over-pressure protection in the industry. • Superior lock-up performance for precise and consistent performance. • Corrosion-resistant materials and coatings for durability. • Positive draining spring case. • 5 Year Warranty. NEE # BTU Capacity Inlet Connection Outlet Connection Adjustment Range Factory Setting Vent Location Internal Relief Bracket R222-BAF 450,000 1/2” F NPT 1/2” F NPT 9 - 13” W.C. 11” W.C. 3/4” F NPT Screened and over outlet Yes P100A R622-BCF 875,000 Over Inlet P100A or P100C R622-CFF 1,400,000 3/4” F NPT 3/4” F NPT Screened and over inlet R622-DFF 3/4” F NPT R652-CFF 1,000,000 1/2” F NPT 3/4” Back Mount 9.5 - 13” W.C. R652-DFF 3/4” F NPT R622-CFGXA 1/2” F NPT 3/4” F NPT 13 - 20” W.C. 18” W.C. 90º R622

NATIONAL TOLL FREE DIRECTORY1-866-574-5100 | ON THE WEBwww.nee.ca REGULATORS DOMESTIC REGULATORS Integral Twin Stage Regulators An Integral Twin Stage Regulator is a two-piece design that combines a separate First Stage Regulator—(complete with an outlet pressure of 2 PSI) with a Second Stage Regulator, designed to provide 11” water column delivery pressure to the appliance all in one convenient housing. These are typically installed on a tank that is located within 30 feet of the appliance or load. This distance can be extended based on the BTU capacity of the application, but care must be taken with line sizing in order to ensure that the appliance inlet pressure requirements are met. Fisher Integral Twin Stage Regulators Features all the benefits of the 600 series in a single compact design; plus with improved flow capacity at cold temperature (-40ºF). The R232A Series is also available with a 90º vent option allowing the unit to be easily mounted under the dome of a cylinder with the vent pointed down. A larger molded diaphragm, dual pressure taps, wrench flat inlet casing, “non- crimped” bonnet assembly and re-designed seat and orifice design all contribute to a regulator with greater capacity and superior lock-up performance that’s easier for the serviceman to install. Fisher has introduced an industry first Twin-Stage compact 2-psig set point regulator (R232E Series ). Along with the improved Full Size series (R632E ), these upgraded Fisher regulator models offer the most diversified end connections in the market. The improved channel flow in the ‘E’ series through the inlet fitting allows for smoother flow and increased capacity. Both the R232E/R632E come complete with a UL-Listed UV protected label for clearer visual identification of the 2 PSI regulator and a white closing cap to further differentiate itself from the R232A Series. NEE # BTU Capacity Inlet Connection Outlet Connection Adjustment Range Factory Setting Internal Relief Vent Location Bracket R232A-BBF 550,000 1/4” F NPT 1/2” F NPT 9-1/2 - 13” W.C. 11” W.C. Yes Over Outlet P100A R232A-BBFXA 90° R232A-HBF F. POL Over Outlet R232A-HBFXA 90° R632A-BCF 850,000 1/4” F NPT 9 - 13” W.C. Over Outlet P100C R632A-BCFXA 90° R632A-HCF F. POL Over Outlet R632A-HCFXA 90° R632A-JFF 3/4” F NPT Over Outlet R632A-JFFXA 90° R632A-CFF 950,000 1/4” F NPT Over Outlet R632A-CFFXA 90° R232E-BBH 500,000 1/2” F NPT 1 - 2.2 PSI 2 PSI Over outlet P100A R232E-HBH F. POL R632E-BCH 850,000 1/4” F NPT P100C R632E-CFH 3/4” F NPT R632E-JFH F. POL R632E-HCH 900,000 1/2” F NPT Fisher Two PSI Regulators Fisher has introduced an industry first Twin-Stage compact 2-psig set point regulator (R232E ). Along with the improved Full Size series (R632E ), these upgraded Fisher regulator models encompass the widest array of end connections in the industry. The improved channel flow in the ‘E’ series through the inlet fitting allows for smoother flow and increased capacity. Both the R232E/R632E come complete with a UL-Listed UV protected label for clearer visual identification of the 2 PSI regulator and a white closing cap to further differentiate itself from the R232A Series. NEE # BTU Capacity Inlet Connection Outlet Connection Adjustment Range Factory Setting Internal Relief Vent Location R622E-BCH 1,250,000 1/2” F NPT 1/2” F NPT 1 - 2.5 PSI 2 PSI Yes Over outlet R622E-DCH 1,500,000 3/4” F NPT 3/4” F NPT 1 - 2.2 PSI R232A R232E

CANADA’S LEADER IN ENERGY PRODUCTS EQUIPMENT REGULATORS DOMESTIC REGULATORS Fisher Automatic Changeover Regulators Changeover regulators consist of an integral two stage regulator & a first stage regulator module connected to two cylinders . Designed to allow automatic changeover when one cylinder empties as they maintain reliable uninterrupted service to the gas appliance when using two cylinders. Ideal for motor homes, RVs & domestic installations. Remote indicators are available for some models, allowing monitoring of cylinder volume at distances up to 10’ from the regulator. NEE # BTU Capacity Inlet Connection Outlet Connection Adjustment Range Factory Setting R962-31 600,000 1/4” Inv. Flare 1/2” F NPT 9 - 13” W.C 11” W.C. Note: Changeover Regulators require 2 pigtails. The ME1663-20 pigtail specifically, is available. Marshall Excelsior Excela-Flo Automatic Changeover Regulators The MEGR-253 Model Automatic Changeover Regulator an integral one piece zinc die cast first and second stage body construction, 1/8”NPT low pressure plugged port, molded lip fabric reinforced diaphragms, high visibility green/ red changeover indicator, high quality glass filled nylon changeover levers and much more. They are available in both our standard and high capacity versions to meet all of your customer’s RV, cottage, or light domestic automatic changeover applications. NEE # Primary Cylinder BTU Reserve Cylinder BTU Inlet Connection Outlet Connection Max Inlet Pressure Covers Mounting Bracket MEGR-253 225,000 150,000 1/4” F Inverted Flare 3/8” F NPT 250 PSI MEGR-862 MEGR-900 or MEGR-RVB MEGR-253H 350,000 200,000 Marshall Excelsior Compact Integral Twin Stage Regulators MEGR-291 two-stage regulators are approved for use in portable applications and outdoor cooking appliances utilizing low pressure. These regulators feature all zinc body construction, high and low 1/8” NPT pressure tap ports, an integral drip lip vent and optional 90 degree vent location. MEGR-291H High Capacity Compact Integral Two Stage Regulators are approved for use in nearly all portable applications and light duty domestic installations. Ideally suited for high demand RV, outdoor appliances, cabins, seasonal homes, gas fireplaces, water heaters, ranges or the other moderate to low demand domestic installations. These regulators feature all zinc body construction, green powder coated bonnets (identify high capacity model), high and low 1/8” NPT pressure tap ports, an integral second stage drip lip vent and optional standard or 90 degree vent locations. The MEGR-291 series regulators meet RVIA, UL, and NFPA test requirements. The MEGR-300 Compact Integral Two Stage 2 PSI Regulator is approved for use in same applications as the 291H Series and are ideally suited for installations to reduce tank pressure to a nominal 2 PSI outlet pressure. 2 PSI systems typically incorporate a line service regulator within the home that further reduces the 2 PSI system pressure to approximately 11” WC prior to the appliance. These regulators feature all zinc body construction, red powder coated bonnets (identify 2 PSI model), high and low 1/8” NPT pressure tap ports, an integral second stage drip lip vent, and optional standard or 90 degree vent locations. The MEGR-300 series compact high capacity integral two stage regulator meets UL, and NFPA requirements. NEE # BTU Capacity Inlet Connection Outlet Connection Adjustment Range Factory Setting Vent Location Internal Relief MEGR-291 175,000 1/4” F NPT 3/8” F NPT 9-13” WC 11” W.C. Over outlet Yes MEGR-298 90° MEGR-295 Excess HN Flow POL MEGR-291-20681 Type 1 QCC Over outlet MEGR-298-20681 90° MEGR-300 225,000 1/4” F NPT N/A 2 PSI Over outlet MEGR-300-90 90° For High Capacity 290 Series Compact Twin Stage Regulators, add an “H” after the part # suffix and increase the BTU Capacity to 225,000. MEGR-253 MEGR-253H MEGR-291 MEGR-291H MEGR-300

NATIONAL TOLL FREE DIRECTORY1-866-574-5100 | ON THE WEBwww.nee.ca REGULATORS DOMESTIC REGULATORS Accessories for Marshall Excelsior Compact Twin Stage Regulators NEE # Description MEGR-861 Universal First Stage Cover - Plastic MEGR-862 Universal Second Stage Cover - Plastic NEE # Description MEGR-900 Universal Z Regulator Bracket 3-1/2” Centerline MEGR-RVB Universal L Regulator Bracket REGULATOR ACCESSORIES Mounting Brackets Provides means to support regulator on walls, posts or other secure surfaces. NEE # For Regulator Shape / Mount P100A (FIS) R122, R232, R600, 912 Triangular P100C R600 Series Universal x Shaped P102A 912 Series Strap NEE # For Regulator Shape / Mount P100A (CAV) 988/998 Series Triangular P100L Universal Rectangular Vent Assemblies Attached directly to the regulator vent connection or vent line, vent assemblies should be pointed downward on outdoor installations to avoid moisture build-up in the spring case. Models with a stabilizer provide a solution to units with instability by giving a restricted breathing rate under normal conditions while opening for rapid discharge, when necessary. The use of vent stabilizers shouldn’t cause restriction to the outlet. They’re designed for use on older Fisher regulators not built with high capacity relief devices or large vent openings. NEE # Size Stabilizer Type Y602-13 1/4” F NPT No Angle Y602-1 1/4” M NPT Umbrella Y602-2 Yes Y602-14 1/4” F NPT Angle Y602-6 3/8” F NPT NEE # Size Stabilizer Type Y602-5 3/8” F NPT No Angle Y602-7 1/2” F NPT Y602-8 Yes ME900-6 3/4” F NPT No Y602-25 1” M NPT Regulator Covers and Hoods In order to ensure proper operation, regulators must be protected from the elements when installed outdoors. When mounted under the dome of a cylinder or tank, they are properly protected. In other applications, a hood or cover is recommended. NEE # Description Dimensions HOOD Galvanized 2-Piece Wall-mounted regulator cover 10 1/2” H x 9 1/2” W x 7” D REGCOVER 1-Piece Polyethylene-hinged regulator cover 13” H x 8” W x 6” D Miscellaneous Regulator Fittings and Adapters NEE # Type Description Application P499 Fisher 1/4” F. Inv Flare x 1/4” M NPT with Screen Convert NPT inlet on regulators such as 912 and 67 series to inverted flare ME2132 Marshall Excelsior 1/4” F. Inv Flare x 1/4” M NPT ME2131 1/4” F. Inv Flare Plug Keeps dirt and foreign material from entering changeover assembly inlets ME24C 1/4” M NPT x 9/16 -18LH Allows connection of a standard welding hose end to the outlet of a 67 series regulator ME24E 3/8” M NPT x 9/16 -18LH Allows connection of a standard welding hose end to 3/8” M NPT METL051 Serviceman’s Friend Regulator test port adapter MEGR-900 MEGR-RVB MEGR-862 P100A P100C Angle Umbrella HOOD REGCOVER P499 ME2131 ME24E METL051

CANADA’S LEADER IN ENERGY PRODUCTS EQUIPMENT REGULATORS SMALL SINGLE STAGE REGULATORS The MEGR-230 Single Stage Regulators are approved for use in small portable applications and outdoor cooking appliances utilizing low pressure. Note: Single Stage Regulators are not approved for RV use or on fixed piping systems for home heating or domestic applications. NEE # BTU Capacity Inlet Connection Outlet Connection Adjustment Range Factory Setting Vent Location Cover MEGR-218 140,000 S.N. FF POL with plastic handwheel 3/8” F NPT 9-13” W.C. 11” W.C. 90º 861-01 MEGR-230-1326 Black F. QCC-1 9” W.C. Over outlet N/A MEGR-230-9 SN .9 GPM Excess Flow POL MEGR-231 Hardnose FF POL 90º 912-101 220,000 1/4” F NPT 11” W.C. Slotted screen Over outlet P331 (To be used when installed horizontally) 912-104 1/4” F NPT 912-122 H.N. M POL 3/8” F NPT 1/8” F NPT Over Outlet 912-197 1/4” F NPT 912-267 Factory set 4.5” W.C. MEGR-230 140,000 9-13” W.C. 9” W.C. Over outlet N/A MEGR-230-90 90º COMMERCIAL & INDUSTRIAL REGULATORS Marshall Excelsior High Pressure Regulators for Small Loads The MEGR-130 series high pressure single stage regulators are designed to provide an economical solution for ‘pounds to pounds’ service applications. The MEGR-130 can be used to regulate air as well as LP gas. Regulators must be installed in compliance with federal, provincial or local codes/laws in accordance with B149. The MEGR-350 series are adjustable high pressure single stage regulators. The body and bonnet of both the fixed and adjustable regulators are precisely machined and feature a crimped design and fabric reinforced rubber diaphragm creating a positive seal for leak-free performance. The MEGR-360 series regulators, with Type 1(QCC), is designed specifically for appliances such as turkey/fish fryers, camp stoves and torch applications that require pounds to pounds pressure instead of inches water column. NEE # BTU Capacity Inlet / Outlet Connection Spring Range Adjustment Type MEGR-130-05 1,200,000 1/4” F NPT Pre-set @ 4 PSI None MEGR-130-10 Pre-set @ 10 PSI MEGR-130-15 Pre-set @ 15 PSI MEGR-130-20 Pre-set @ 20 PSI MEGR-130-30 Pre-set @ 30 PSI MEGR-350 0-10 PSI Dial Top MEGR-350-20 0-20 PSI MEGR-350-30 0-30 PSI MEGR-351 Full Flow POL x 1/4” F NPT 0-10 PSI MEGR-360 Black F.QCC x 1/4” F NPT MEGR-230 Regulator with “Drip Lip” vent MEGR-230-9 MEGR-230 with Soft-Nose 912 Series MEGR-130-20 MEGR-350

NATIONAL TOLL FREE DIRECTORY1-866-574-5100 | ON THE WEBwww.nee.ca REGULATORS COMMERCIAL & INDUSTRIAL REGULATORS High Pressure and Adjustable Regulators Fisher 67 Series High Pressure Regulators Dial Adjustment Type Suitable for liquid or vapour applications with various adjustment options and spring ranges. Typical applications include torches, construction heaters, power wash heaters, tar pots, etc. The 67 Series Regulators include a plugged 1/4” F NPT side port for use with a pressure gauge that is ordered separately. NEE # BTU Capacity Inlet / Outlet Connection Spring Range Set Pressure 67CD-101 750,000 1/4” F NPT 5-30 PSI 20 PSI 67CD-104 1,200,000 M POL / 1/4” F NPT 20-50 PSI 40 PSI 67CD-102 1/4” F NPT 67CD-103 1,000,000 40-100 PSI 50 PSI Wrench Adjustment Type NEE # BTU Capacity Inlet / Outlet Connection Spring Range Set Pressure 67CW-684 750,000 1/4” F NPT 3-35 PSI 20 PSI 67CW-701 1,000,000 50-130 PSI 50 PSI 67CW-687 M POL / 1/4” F NPT 67CW-685 1,200,000 1/4” F NPT 30-60 PSI 40 PSI Non-Adjustment Type NEE # BTU Capacity Inlet / Outlet Connection Spring Range Set Pressure 67CN-106 400,000 1/4” F NPT Non-Adjustable 10 PSI 67CN-104 600,000 15 PSI 67CN-105 750,000 20 PSI Handwheel Adjustment Type NEE # BTU Capacity Inlet / Outlet Connection Spring Range Set Pressure 67CH-743 750,000 1/4” F NPT 3-35 PSI 20 PSI 67CH-745 M POL / 1/4” F NPT 67CH-741 1,000,000 1/4” F NPT 50-130 PSI 50 PSI 67CH-742 1,200,000 30-60 PSI 40 PSI The MEGR-6120 Series are UL listed high-pressure regulators that meet a variety of applications in liquid or vapour service. The compact body design makes these regulators particularly useful in installations with space limitations. The basic MEGR-6120 Series regulators come equipped with a handwheel adjustment. Marshall Excelsior 6120 Series High Pressure Regulators Handwheel Adjustment Type NEE # BTU Capacity Inlet / Outlet Connection Spring Range Set Pressure MEGR-6120-30 850,000 1/4” F NPT 1-30 PSI 15 PSI MEGR-6120-60 1,500,000 1-60 PSI 40 PSI MEGR-6120-100 1,800,000 1-100 PSI 50 PSI

CANADA’S LEADER IN ENERGY PRODUCTS EQUIPMENT REGULATORS COMMERCIAL & INDUSTRIAL REGULATORS High Pressure and Adjustable Regulators Fisher 64 Series High Pressure Regulators These high pressure (pounds to pounds) regulators usually reduce tank pressure to an intermediate pressure for use by another regulator. They may be used on a distribution system when used with a first stage regulator downstream in the piping system. The 64SR (with internal relief) may be used as a first stage regulator when set at 10 PSI. Suitable for liquid or vapour at temperatures below 150º F, these regulators are popular for use with crop dryers, high pressure burners and other medium sized commercial/industrial applications. A 1/4” plugged side outlet can be used to install a pressure gauge or hydrostatic valve. NEE # BTU Capacity Inlet / Outlet Connection Spring Range Set Pressure Features 64-33 2,265,000 1/2” F NPT 3-15 PSI 10 PSI No Relief 64-35 3,600,000 5-35 PSI 20 PSI 64-36 4,150,000 30-60 PSI 40 PSI 64-222 5,250,000 35-100 PSI 50 PSI 64SR-21 3,600,000 3-15 PSI 20 PSI With Relief 64SR-22 5-20 PSI 64SR-23 5-35 PSI 64KB Series Suitable for NH3 Applications NEE # Inlet / Outlet Connection Spring Range Set Pressure CFH (NH3) Capacity * Features 64KB/33 1/2” F NPT 3-15 PSI 10 PSI 2,265,000 No Relief 64KB/34 5-20 PSI 15 PSI 3,000,000 64KB/36 30-60 PSI 40 PSI 4,150,000 64KB/222 35-100 PSI 50 PSI 5,250,000 * Liquid Capacity is 145 GPH at inlet pressures 20 PSIG above set point. Suitable for NH3 applications due to the 64KB’s special diaphragm protector High & Low Pressure Regulators for Large Loads Fisher 299H Series Low Pressure Regulators The Fisher 299H Series model is a high capacity, pilot-operated regulator , incorporating a lightweight, 21 pounds / 9,5 kg design with dependable operation. With a capacity up to 38 million BTU/hr / 428 SCMH, the ype 299H is ideal for applications from large commercial sites to smaller multi-dwelling establishments. The unit comes with a 1-1/2 or 2-inch threaded NPT cast iron body with internal or external registration. Internal registration allows easy installation while external registration provides higher accuracy. A 2-inch / DN 50 flanged body and steel body material are also available. Alternate outlet settings from 3.5-inches w.c. / 9 mbar to 60 psig / 4,14 bar are available. The 299H model has a maximum inlet pressure rating of 150 psig / 10,3 bar, so it cannot be used as a first- stage regulator. NEE # BTU Capacity Orifice Size Inlet / Outlet Connection Pressure Range Set Pressure Features 299H-101 13,100,000 3/4” 1 1/2” F NPT 9-20” W.C. 11” W.C. Pilot Operated 299H-102 2” F NPT 299H-103 23,300,000 1 1/2” F NPT 6 - 16 PSIG 10 PSIG 299H-104 38,000,000 2” F NPT 299H-105 20,400,000 1 1/2” F NPT 9-20” W.C. 11” W.C. 299H-106 2” F NPT 299H-107 38,000,000 1 1/2” F NPT 6 - 16 PSIG 10 PSIG 299H-108 2” F NPT

NATIONAL TOLL FREE DIRECTORY1-866-574-5100 | ON THE WEBwww.nee.ca REGULATORS COMMERCIAL & INDUSTRIAL REGULATORS High & Low Pressure Regulators for Large Loads Fisher offers a variety of first and second stage regulators to meet requirements in excess of 100 million BTU/hr. NEE # BTU Capacity Inlet / Outlet Connection Orifice Spring Range Set Pressure Features 627-5810 6,080,000 3/4” F NPT 3/8” 5-20 PSI 10 PSI Requires External Relief 627-5810V 627-6210 10,755,000 1/2” 627-6210V 627-7710 10,773,000 1” F NPT 627-7710V 627R-197 With Internal Relief 630-104-78 14,000,000 2” F NPT 8-20 PSI Requires External Relief 99-510P 29,295,000 7/8” 1/4” - 2 PSI - Pilot Operated 99-513P 2-10 PSI 99-515P 36,225,000 10-20 PSI 99-504P 61,200,000 1 1/8” 5-15 PSI 99-901P 10-65 PSI 99-504PH 63,200,000 5-15 PSI HSRL-BFC 2,100,000 3/4” F NPT 3/8” 9-13” W.C. 11” W.C. High Capacity Internal Relief HSRL-CFC 1” F NPT HSRL-PFC 2,300,000 3/4” F NPT 90° HSRL-SFC 2,600,000 1” F NPT 90° 133H-1 113,400,000 2” F NPT 2” 1 1/2” - 3 PSI 3 PSI Max Inlet Pressure= 60 PSI 133H-2 2-5 PSI 133H-4 66,000,000 1 1/2” - 3 PSI133L-4 70,875,000 8 1/2” - 18” W.C. 14” W.C. Note: ‘V’ Option available for high temperature applications up to 300°F. Recommended for use with vaporizer applications. Other spring ranges and capaciti s available, cont ct NEE for specificati ns. 627 Series 133 Series 630 Series 99 Series HSRL Series

CANADA’S LEADER IN ENERGY PRODUCTS EQUIPMENT REGULATORS COMMERCIAL & INDUSTRIAL REGULATORS High & Low Pressure Regulators for Large Loads Fisher CS Series Low Pressure Regulators The CS200, CS400 & CS800 Series direct-operated, spring-loaded regulators were engineered to fit a myriad of pressure-reducing applications. The CS200 & CS400 models include commercial & industrial installations, while the CS800 model includes low pressure commercial service installations. Flexibility is provided by the many body sizes, outlet pressure settings & orifice sizes. Ease of maintenance & installation is a strength of the CS200 Series, offering a 360° rotation of the actuator via the union ring connection between the body & casing. The combination of the 360° rotatable union ring/upper casing provides a simplified vent position, especially in tight spaces or awkward installations. To provide further flexibility, the CS200/400/800 Series regulators offer overpressure protection via internal relief. Secondary Seat ™ Protection is an available option. Additional downstream pressure protection may be required based on application circumstances. CS800 Series regulators can accommodate up to 21,600,000 BTU per hour/243 SCMH of flow capacity and are available in 1-1/2” & 2” body sizes with 8” W.C. to 5.5 psig pressure ranges. NEE # BTU Capacity Inlet / Outlet Connection Orifice Size Spring Range Set Pressure Features CS200IR-6CC1 2,194,000 3/4” F NPT 1/2” 6-8” W.C. 11” W.C. With Standard Internal Relief CS200IR-6EC1 2,546,000 10-14” W.C. CS200IR-6FC1 12-19” W.C. CS200IR-6HC1 3,685,700 1-2” PSI CS200IR-6CC3 3,252,000 1” F NPT 6-8” W.C. CS200IR-6FC3 12-19” W.C. CS200IR-6EC3 3,761,000 10-14” W.C. CS200IR-6HC3 5,406,000 1-2” PSI CS200IR-6CC6 3,840,000 1 1/4” F NPT 6-8” W.C. CS200IR-6EC6 10-14” W.C. CS200IR-6FC6 12-19” W.C. CS200IR-6HC6 7,680,000 1-2” PSI CS400IR-8EC6 6,867,000 3/4” 10-14” W.C. CS400IR-8EC7 7,600,000 1 1/2” F NPT CS400IR-8EC8 2” F NPT CS800IR-8CC7 10,200,000 1 1/2” F NPT 1” 8-12” W.C. CS800IR-8CC8 21,600,000 2” F NPT Repair Kits NEE # For Model # R627X000A12 627-5810 / 6210 / 7710 NEE # For Model # R630X000L22 630-104 / 78 Fisher Industrial Automatic Changeover Assemblies & Manifolds Changeover Assemblies (Manifold & Final Stage Regulator) Fisher Commercial Changeover Assemblies are designed for large capacity multi-cylinder or tank installations such as bakeries, motels, restaurants and crop dryers. The 64SR-122 first stage manifold consists of the two 64 series regulators and a direct mounted 803 indicator. NEE # BTU Capacity Inlet Connection Outlet Connection Adjustment Range Factory Setting Features 64SR-122 1,210,000 1/2” F NPT 1/2” F NPT 5 - 20 PSI 10 PSIG With internal relief Fisher Commercial Changeover Manifolds are intended for use with second stage regulators and/or separate relief devices which provide the overpressure protection required by code. The capacity of these manifolds is dependent on the size of the second stage regulator used in the piping system. Changeover Manifolds (Manifolds Only) NEE # BTU Capacity Inlet Connection Outlet Connection Supply Setting Reserve Setting Features R110-21 500,000 1/4” Inv Flare 1/4” F NPT 15 PSI 7 PSI With indicator 749B-21 1,500,000 1/2” F NPT 1/2” F NPT 5 PSI Two 64 series regs CS200 Series CS400 Series CS800 Series R110-21 749B-21

NATIONAL TOLL FREE DIRECTORY1-866-574-5100 | ON THE WEBwww.nee.ca REGULATORS GAS PRESSURE REGULATORS Maxitrol Rubber Seat Poppet Design Regulators These rubber seat poppet type regulators are designed primarily for main burner and pilot load applications where precise control of tiny flows is an essential operating requirement. They may be used with natural, manufactured, mixed, LP, or LP gas-air mixture. NEE # Connections Capacities² to Inlet Pressures to Outlet Pressures to RV12 1/8” x 1/8”¹, 3/16” Lox x 3/16” Lox 25 ft³ / h (0.7m³/h) 1/2 PSI (35 mbars) 1.0” to 12” WC (2.5 to 30 mbars) RV20 1/4” x 1/4”, 3/8” x 3/8”¹ 65 ft³ / h (1.8m³/h) RV47 and CV47 3/8” x 3/8”, 1/2” x 1/2”¹ 125 ft³ / h (3.5m³/h) RV48 1/2” x 1/2”, 3/4” x 3/4” 250 ft³ / h (7m³/h) ¹ Available as Loxit connection ² Minimum main burner regulation capacity is 150 BTU/hr (.0042m³/h) Maxitrol Straight-Thru-Flow (STF) Design Regulators NEE # Connections¹ Capacities to Inlet Pressures to Outlet Pressures to RV52 1/2” x 1/2”, 3/4” x 3/4” 900 ft³/h (25m³/h) 1/2 PSI (35 mbars) 1.0” to 12” WC (2.5 to 30 mbars) RV53 3/4” x 3/4”, 1” x 1” 1300 ft³/h (36m³/h) RV61 1” x 1”, 1 1/4” x 1 1/4”” 2500 ft³/h (70m³/h) 1 PSI (70 mbars) 1.0” to 22” WC (2.5 to 55 mbars) RV81 1 1/4” x 1 1/4”, 1 1/2” x 1 1/2” 4500 ft³/h (127m³/h) RV91 2” x 2”, 2 1/2” x 2 1/2” 7500 ft³/h (212m³/h) RV111 2 1/2” x 2 1/2”, 3” x 3” 17,000 ft³/h (481m³/h) *All models tapped with NPT vent bosses. RV12 RV20 RV47 / CV47 RV48 RV52 RV53 RV61 RV81 / RV91 RV111 Maxitrol’s original Straight-Thru-Flow Design meets your needs for high capacities at low inlet pressures. The basic difference between the initial model and the current S-T-F design is that it delivers higher outlet pressure than the spring loaded models. The main diaphragm is loaded with gas pressure rather than with a spring. The gas pressure of the main diaphragm is precisely controlled by a small pilot regulator within the upper housing.

CANADA’S LEADER IN ENERGY PRODUCTS EQUIPMENT REGULATORS GAS PRESSURE REGULATORS Maxitrol Lever Acting Design Regulators 325 Series Appliance Pressure Regulators The 325 Series is a ‘pounds-to-inches’ high performance regulator, meeting utility specifications; for use on residential, commercial & industrial applications where adequate inlet pressures are available. Can be used as a single stage regulator; reducing ‘pounds-pressure’ to normal burner pressure. Certified byCSA: ANSI Z21.18/CSA 6.3. The 325-3 and 325-5A models are certified and accepted as an appliance regulator. The 325-7 model is designed especially for the growing equipment segment with electronic ignition. It permits utilization of greater capacities without sacrificing performance. To deliver positive dead-end lockup, the 325 Series features high leverage valve linkage assembly. Lockup pressure varies with the speed & location of the solenoid valve. These units are capable of precise regulating control from full flow down to pilot flows. Maxitrol’s new 325 Series are certified for up to 5-PSI inlet pressure, with the 7 to 11 (inches of W.C. [Water Column] outlet) spring. These are Class 1, ‘pounds-to-inches’ regulators. At supply pressures in excess of 2-PSI, the new line regulator standard requires a means (an over pressure protection device/OPD)- approved and tested with the regulator – to limit the downstream pressure to 2-PSI maximum, in the event of regulator failure. Maxitrol–built OPDs provide the required downstream over-pressure protection. NEE # Connections Capacities to Inlet Pressures to Outlet Pressure Range (CSA Certified) 325-3 3/8” x 3/8”, 1/2” x 1/2” 100,000 BTU/hr 5 PSI 6” to 10” WC 325-5A 1/2” x 1/2”, 3/4” x 3/4”, 1” x 1” 250,000 BTU/hr 7” to 11” WC 325-7 1 1/4” x 1 1/4”, 1 1/2” x 1 1/2” 1,250,000 BTU/hr Not certified Have your NEE Representative drop off some Maxitrol literature which provides detailed specifications and application calculations ! There are more variations of each product series listed The L-Models are Class 1, ‘pounds-to-inches’ regulators; meeting utility specifications, for use on 2-PSI piping systems such as CSST semi-rigid copper tubing. The regulators are a high performance type – reducing pounds pressure to a level within the appliance’s operating supply range. Located upstream of equipment already fitted with an appliance regulator, this line pressure regulator is certified by ANSI Z21.80/CSA 6.22. 325 Series Line Pressure Regulators NEE # Connections Capacities to Inlet Pressures to Outlet Pressure Range (CSA Certified) 325-3L 3/8” x 3/8”, 1/2” x 1/2” 140,000 BTU/hr 2 PSI 7” to 11” WC 325-5AL 1/2” x 1/2”, 3/4” x 3/4”, 1” x 1” 300,000 BTU/hr 325-7L 1 1/4” x 1 1/4”, 1 1/2” x 1 1/2” 1,250,000 BTU/hr Have your NEE Representative drop off some Maxitrol literature which provides detailed specifications and application calculations ! There are more variations of each product series listed 325-3 325-5A 325-7 325-3L 325-5AL 325-7L

NATIONAL TOLL FREE DIRECTORY1-866-574-5100 | ON THE WEBwww.nee.ca REGULATORS GAS PRESSURE REGULATORS Maxitrol Lever Acting Design Regulators 325 Series Line Pressure Regulators with Over-Pressure Protection Devices The 325 Series with OPDs (Over-Pressure Protection Devices) features a high leverage valve linkage assembly to deliver positive dead-end lock-up. The regulators are capable of precise regulating control from full flow down to pilot flow. Certified byCSA: ANSI Z21.18/CSA 6.3. NEE # Connections Capacities to Inlet Pressures to Outlet Pressure Range (CSA Certified) 325-3L48 3/8” x 3/8”, 1/2” x 1/2” 200,000 BTU/hr 5 PSI 7” to 11” WC 325-3L47 125,000 BTU/hr 325-5AL48 1/2” x 1/2”, 3/4” x 3/4”, 1” x 1” 235,000 BTU/hr (@ 1/2”), 320,000 BTU/hr (@ 3/4”) 325-5AL600 425,000 BTU/hr (@ 3/4”), 465,000 BTU/hr (@1”) 325-3L47 325-5AL600 Have your NEE Representative drop off some Maxitrol literature which provides detailed specifications and application calculations ! There are more variations of each product series listed Maxitrol Accessories for Gas Pressure Regulators Various accessories are available for Maxitrol regulators which are designed for universal acceptance among utilities. Vent limiters are not recommended for use in models: RV91, RV111, RV131 and 210 Series . Maxitrol should be consulted when used with model RV81 . * Consult NEE / Maxitrol regarding vent limiter use. ** Vent protector must be mounted in an upright position. *** Vent limiters are not recommended for use in RV91 and 210 Series models. Vent Tube Connector Vent Limiting Means Pressure Tap Connector Nut Vent Dampener Vent Protector Dust Cap Vent Screen

CANADA’S LEADER IN ENERGY PRODUCTS EQUIPMENT CYLINDER & TANK VALVES MULTI VALVES Sherwood 2030/2035 Series Multi Valves for DOT Cylinders & ASME Tanks Sherwood Multi Valves incorporate a vapour service valve, 1-3/4” ACME double back check fill valve, 80% liquid level indicator and relief device in one valve. They are typically used in 100 to 420 Lb. DOT cylinders and 123 USWG ASME tanks equipped with a single opening. Relief valve settings of 250 PSI are for ASME rated tanks and 375 PSI is for DOT Cylinders. These valves are now equipped with an exclusive “Gas Check Ready ” feature incorporating a 1/8” NPT gauge port downstream of the shut-off seat that allows the serviceman to perform numerous tests including: • System Leak Testing • Out of Gas – Pressure Testing • Service Valve Seat Testing • Complete Gas Check Testing; (without breaking the gas tight service connection) Replaces test block gauge adapters and is compatible with all first stage regulators on the market. Utilizes the Presto-Tap Schrader Valve, which is available separately. (** Item #’s with a “T” in the part # code utilize this feature) Features: • Spray-fill design for fast filling • Teflon-coated stem assemblies for long life • Optional Everseal thread coating for reduced installation costs. Note: Substitute PVE for PV for the Everseal option. NEE # Inlet Siz Relief Setting Outlet Dip Tube Length Application Repair Kit PV2030BC-11.6 3/4” NGT 375 PSI POL 11.6” Up to 200 # Cylinders 2030-100-KIT, 3329-13LH-KIT PV2035AT-11.1 1” NGT 11.1” Up to 400 # Cylinders 2035-100-KIT, 3250-8LH-KIT PV2035AT-11.6 11.6” PV2035AT-11.7 11.7” PV2035AT250-11.1 250 PSI 11.1” 123 # ASME Tanks PV2035AT250-12.0 12.0” PVE2035AT250-11.6 11.6” Sherwood 2033/2034 Series Multi Valves Sherwood PV2033 and PV2034 series valves are used in ASME tanks that are equipped with separate relief and fill valves. Valves with a DB suffix incorporate a Dual Bonnet feature that allows a leaking stem and bonnet assembly to be repaired without interrupting the gas service. PV2033 valves are used in applications that utilize vapour equalizing when tank filling. The PV2034 is used when vapour equalizing is not required. NEE # Inlet Size Vapour Return Valve Outlet Dip Tube Length Dual Bonnet Feature Repair Kit PV2033CLDBT-12.6 3/4” NGT Yes - 1 1/4” ACME POL 12.6” Yes 2033-100-KIT, 6775-60-KIT PV2033CLT-12.6 No 2033-100-KIT PVE2034CLT-11.8 No 11.8” 3329-13LH-KIT Cavagna Multi Valves NEE # Inlet Size Relief Setting Outlet Dip Tube Length Application 67-0808-11.6 3/4” NGT 375 PSI POL 11.6” 100 - 200 # DOT Cylinders 67-0808-8.5 8.5” 67-0720-12.6 No Relief Valve 12.6” Vapour Equalizing ASME Tanks 80-3135-11.1 11.0” 420 # DOT Cylinders PV2030BC PV2035A PV2034CL PV2033L 67-0720

NATIONAL TOLL FREE DIRECTORY1-866-574-5100 | ON THE WEBwww.nee.ca CYLINDER & TANK VALVES VAPOUR & LIQUID SERVICE VALVES, LIFT TRUCK CONNECTORS Liquid Service Valves for Auto Propane Applications Designed for use in Auto Propane Tanks, these valves are equipped with both an internal excess flow valve and a 3⁄8” SAE flare outlet service connection. NEE # Manufacturer Tank Connection Size Outlet Excess Flow Valve Notes Repair Kit ME9101H4 Marshall Excelsior 3/4” NGT 3/8” SAE Flare 1.5 GPM Dual O-Ring Packing Design & Universal Bonnet Assembly ME9101P5BRK ME9101H6 2.6 GPM PV1447C Sherwood 1.7 GPM Compact - Lowest Profile 3329-13LH-KIT PV1447D Standard Full Size Valve * 3250-8LH-KIT PV1447DMF 2.5 GPM Angled SAE Outlet * * Offers Integral Hydrostatic Relief Liquid Service Valves for Forklift Cylinder Applications Designed for use in Forklift Cylinders. these valves are equipped with both an internal excess flow valve and a 3/8” M NPT connection. NEE # Manufacturer Tank Connection Size Outlet Excess Flow Valve Notes Repair Kit ME9101P5 Marshall Excelsior 3/4” NGT 3/8” M NPT 1.5 GPM Dual O-Ring Packing Design & Universal Bonnet Assembly ME9101BRK ME9101P5H 2.6 GPM PVE1449 Sherwood 1.7 GPM Compact - Lowest Profile 3329-13LH-KIT PV1427C Smaller Body & Bonnet PV1427B Standard Full Size Valve 3250-8LH-KIT 80-2064 Cavagna 2.6 GPM Compact - Low Profile Non - Repairable 73-0001 5/8” UNF 1.4 GPM Electric Solenoid Service Valves - -- Cavagna’s Compact, Low-profile reduces potential for valve damage when cylinders are stacked on top of each other. Sherwood Liquid Service Valve Replacement Parts NEE # Description EV1448 LPG Solenoid Service Valve 1448-5 Replacement 12 Volt Coil for EV1448 NEE # Description 67-1449-7 Handwheel for PVE1449 PV1447 PV1447DMF ME9101H4 ME9101P5H 80-2064 PVE1449 PV1427C PV1427B

CANADA’S LEADER IN ENERGY PRODUCTS EQUIPMENT CYLINDER & TANK VALVES VAPOUR & LIQUID SERVICE VALVES, LIFT TRUCK CONNECTORS Vapour Cylinder Valves NEE # Type Inlet Size Relief Valve Setting Outlet Dip Tube Length Application Repair Kit PV3250AD-7 Sherwood 3/4” NGT No Relief POL None 200 and 420 Lb Cylinders 3250-8LH-KIT PV3250CLM-11.6 375 PSI CGA 555 11.6” 100 Lb Cylinders Liquid Withdrawal PVE3250BC-312 312 PSI POL None ASME Motor Fuel Tanks 3329-13LH-KIT PVE3250C-375 375 PSI 100 Lb Cylinders 3250-8LH-KIT PVE3250CLG10.6 10.6” PVE3250CLG11.6 11.6” PVE3250CLG9.6 9.6” PVE3329BLGT-11.0 No Relief 11.0” 200 and 420 Lb Cylinders 3329-13LH-KIT PVE3329BLGT-11.1 11.1” PVE3329BLGT-11.7 11.7” ME9101C1 Marshall Excelsior None ME9101C1BRK 80-2146 Cavagna - 80-3135-11.1 11.0” 80-3135-11.7 420 Lb Cylinders V13380 SCG 100# 375 PSI None 100 Lb Cylinders V20643 9.6” * ME9101C5 comes complete with a 2.6 GPM Excess Flow Valve Marshall Excelsior Cylinder Valves are intended for use in vapour withdrawal service for ASME and DOT containers or as fuel line shutoff valves. Comes complete with: One piece forged brass body construction, dual o‐ring packing design, universal (easy to repair) bonnet assembly and heavy duty replaceable zinc hand wheel. Cavagna Cylinder Valves are designed for vapour or liquid withdrawal service on ASME containers. Comes complete with heavy duty rugged forging, double o-ring seal for longer valve life, easy to grip large handwheel. Sherwood Cylinder Valves for DOT cylinders incorporate an integral relief valve, forged brass body, non-rising nylon seat and a Teflon-coated stem assembly to ensure long operating life and a positive back seat. Valves with a PVE prefix are supplied with Everseal thread sealant as standard for reduced installation costs. The 3250AD and 3329BLGT series valves are used as a vapour service valve on DOT cylinders equipped with a separate relief valve. The 3250AD-7 valve, in particular, comes complete with a pre-tapped pressure test port. SCG 100# Cylinder Valves come only in the 100 lb - POL variety, with diptube option. SCG #100 Series ME9101C1 PV3250BC-312 PV3250AD-7 PVE3329BLGT

NATIONAL TOLL FREE DIRECTORY1-866-574-5100 | ON THE WEBwww.nee.ca CYLINDER & TANK VALVES QCC TYPE 1 OPD CYLINDER VALVES OPD Cylinder Valves D.O.T. & T.C. Propane cylinders up to 40 Lbs capacity manufactured or recertified after January 1st 2008 must be equipped with an OPD valve. The patented Sureflame valve incorporates the OPD feature as well as a float gauge mechanism that accurately displays the cylinder volume, making it easy to know if it’s “Time to Grill or Time to Fill”. Features:  A back check module that prevents the flow of gas unless a connection is made  A unique 1- 5/16” right hand male ACME thread(CGA connection 791), designed specifically for thermally protected female connectors  Internal POL threads to allow older POL devices to be connected  Relief valve capacity rated for cylinders up to 40 Lb  A triangular handwheel on OPD valves for easy identification Note: As required by code, all OPD Valves are built with non-repairable stem & bonnet assemblies. NEE # Dip Tube Length Application V21113 3.0 5# Cylinders V21130 3.6 10#, 11# Cylinders V21109 4.0 20# Cylinders 80-8180 20# Cylinders, with outage V21463 20# Cylinders, with Sureflame gauge feature, without dial NEE # Dip Tube Length Application V21464L 4.0 20# Cylinders, with Sureflame gauge feature, with dial V20691 4.7 30# Cylinders 150361 - 30# Cylinders, with Sureflame gauge feature V21110 6.5 40# Cylinders

CANADA’S LEADER IN ENERGY PRODUCTS EQUIPMENT CYLINDER & TANK VALVES LIFT TRUCK CYLINDER & MOTORFUEL TANK VALVES Fork Lift Cylinder Relief Valves Sherwood DOT/TC Cylinder Relief Valves for forklift cylinders have a 375 PSI setting and must be installed with a Pipe-away adapter in order to ensure that any discharge is directed away from the operator when the cylinder is in use. The PV435L valve is a low profile valve designed for use in older cylinders that have a shorter coupling that causes the PV435A valve to bottom out. Marshall Excelsior Forklift Cylinder Relief Valves are designed for use on forklift cylinders and other DOT/TC Portable cylinders up to 122 pounds of LP-Gas capacity. The working components of the MEV75FIR valve are located inside the tank, reducing possible malfunction caused by outside debris or other foreign materials. Cavagna Forklift Relief Valves are UL Listed and designed for DOT/TC forklift cylinders. All Lift truck cylinders must have the relief valve replaced every 10 years with a new unused relief valve. Relief valve must be protected with a raincap when in service. NEE # Tank Connection Size Relief Valve Setting Notes 66-0248 3/4” NGT 375 PSI Safety Relief Valve MEV75FIR Longer Spring Fork Lift Cylinder Relief Valve Accessories NEE # Description 10-5038 Plastic plug & strap, for 3/4” - 66-0248 MEP175C Protective rain cap for MEV75FIR valve, with lanyard MEP175P Protective plug for MEV75FIR & MEH25 Series valves NEE # Description 435-45C Protective rain cap for PV435 Series valve or pipe-away 435-45 45º Pipe-away adapter, for PV435 435-90 90º Pipe-away adapter, for PV435 Dual Tank Connector The PV3866 combines a bulkhead with two check valves and a hydrostatic relief valve. This valve is designed to connect two motorfuel tanks to a single line that runs to the fuel lock-off and allows the two tanks to operate at the same time without product flowing from one tank to the other. NEE # Inlet Outlet PV3866 2 x 3/8” Male flare 3/8” Male Flare Bulkhead MEV75FIR 435-45 PV435A PV435L 435-45C 10-5038 66-0248

NATIONAL TOLL FREE DIRECTORY1-866-574-5100 | ON THE WEBwww.nee.ca CYLINDER & TANK VALVES LIFT TRUCK CYLINDER & MOTORFUEL TANK VALVES Lift Truck Connectors These 1-1/4” ACME connectors are interchangeable with all 1-1/4” ACME fork lift applications and are designed to prevent the flow of gas from either the male or female connector, unless they are connected. NEE # Type Inlet Outlet ME220M Marshall Excelsior 3/8 F NPT 1 1/4” M. ACME ME220F 1 1/4” F. ACME 1/4” F NPT 66-1024 Cavagna 3/8 F NPT 1 1/4” M. ACME Accessories NEE # Type Description G114B RPM Mechanical Inner O-Ring for Female Connector ME220FP Marshall Excelsior Brass Cap for ME220M / 66-1024 applications NEE # Type Description MEW4 Marshall Excelsior ACME Washer for ME220M Flange Adapter Relief Valves for ASME / DOT Motorfuel Tanks NEE # Tank Connection Size Relief Setting Pipe-away Adapter UV445AM 1” 250 PSI 445-21 (cap= P206) 66-1128 3/4” 30-0274 66-1162 312 PSI 10-5036 66-1127 1” 375 PSI 10-5032 66-1129 250 PSI 30-0273 66-1135 10-5032 66-1242 312 PSI66-1130 1 1/4” 250 PSI 30-0276 Accessories NEE # Description 10-5032 Plastic Plug for 1” 66-1127/1135 10-5033 Plastic Plug for 1” 66-1129 10-5056 Plastic Plug for 1” 66-1162/1027 10-5037 Plastic Plug for 1 1/4” 66-1130 10-0203 Plastic Plug & Strap, for 3/4” 66-1128 10-0204 Plastic Plug & Strap, for 1” 66-1129 NEE # Description 10-0205 Plastic Plug & Strap, for 1 1/4” 66-1130 30-0273 Vinyl Relief Cap, for 3/4” 66-1129 30-0274 Vinyl Relief Cap, for 1” 66-1128 30-0276 Vinyl Relief Cap, for 1 1/4” 66-1130 51C1100001 Valve Socket, 1/2” drive, for Cylinder Valves * * Fits all OPD valves, Forklift valves and POL Service valves ME220F ME220M UV445AR

CANADA’S LEADER IN ENERGY PRODUCTS EQUIPMENT CYLINDER & TANK VALVES VALVES & ADAPTERS FOR LARGE TANKS AND BULK PLANTS Relief Valve Manifolds The A1416 relief valve manifold is used on large NH3 tanks to allow removal of a relief valve for inspection or replacement without the need of evacuating the tank. Adequate relief protection must be provided by the remaining relief valve in the manifold. Bleeder valves relieve vapour pressure under each relief valve after closing the manifold port, and each port can be closed separately, meeting code requirements. Soft seats allow bubble tight closure of each port. The ME904S Series is designed for use with large LPG & NH3 stationary storage containers with flanged openings. These Relief Manifolds have an additional relief valve excluded from the flow rating, which allowing for service and/or exchange of any one relief valve without evacuating the tank. Features Heavy duty ductile iron body, durable V-cup Teflon packing stem seals, Molded rubber weather guard for manifold rotary gear with port plug & integral break- away component, leaving seat and seal intact. Available with Nitrile or Viton trim. Also available for NH3 applications with a 265 PSI Setting. NEE # Tank Connection Size Start to Discharge Setting # of Relief Valves Includes A1416 2” F NPT -- 2 Body only ME904S-3F/250CN 3” 300# Modified ANSI Flange 250 PSI 4 Manifold + 4 Valves ME904S-3F/250VM ME904S-4F/250CN 4” - 300# Flange ME904S-4F/250VM Notes for A1416: - Relief Manifolds options include A1416A (2” FNPT, 250 PSI) & A1416B (2” FNPT, 265 PSI) - Relief Valves sold separately (A1310A & A1310B ) for A1416A & B respectively - Furnished with 2” X 2” MNPT Nipple - Container relief capacity requirements must be met with 1 valve. Accessories NEE # Description MEP104-24 3” FNPT x 3” FNPT Pipe-away Adapter, with Breakaway Groove NEE # Description ME904SK 8 Stud/Nut Universal Mounting Kit Internal Relief Valves for Domestic Storage Tanks Relief valves are designed to protect the container they are installed in, and they must be capable of relieving a volume that is determined by the size of the tank. When sizing a relief valve for a specific container, review the manufacturer’s data to confirm that the flow capacity of the valve is adequate. NEE # Tank Connection Size Relief Setting Protective Cap Application UV433AM 3/4” 250 PSI 433-45A 123 - 320 USWG ASME Tanks UV443AM 1” 443-45A 500 USWG ASME Tanks UV445AM UEP16Y 123 USWG ASME Tanks UV453AM 1 1/4” 453-45A 1000 USWG ASME Tanks PVE445AT 1” 375 PSI UEP16Y 420 # DOT Cylinders ME904S A1416 UV Series

RkJQdWJsaXNoZXIy NDE1MjE4