FIBERGLASS - COMPOSITEPIPEGROUP - HEADQUARTERS 9720 Cypresswood Dr., Suite 325 • Houston, TX 77070 • Tel: (832) 912-8282 • Fax: (832) 912-9393 • http://www.ameron-fpg.com Europe Ameron B.V. J.F. Kennedylaan 7 4191 MZ Geldermalsen The Netherlands Tel: +31 345 587 587 Fax: +31 345 587 561 email: [email protected] Americas P.O. Box 878 Burkburnett, TX 76354 Tel: (940) 569-1471 Fax: (940) 569-2764 email: [email protected] Centron International P.O. Box 490 600 FM 1195 South Mineral Wells, Texas 76068 Tel: (940) 325-1341 Fax: (940) 325-9681 Asia Ameron (Pte) Ltd. No. 7A, Tuas Avenue 3 Singapore 639407 Tel: 65 6861 6118 Fax: 65 6862 1302/861 7834 email: [email protected],sg © 1997 AmeronFP737F (11/07) supercedes FP737E (01/02) Printed in U.S.A. Bending radius Minimum Maximum Minimum Nominal Bending Deflection Length Required Pipe Size Radius1 per 20-ft Joint for 10° Change (in) (mm) (ft) (m) (deg) (ft) (m) 2 50 75 23 15 13 4 3 80 125 38 9 22 7 4 100 150 46 7.5 27 8 1) At rated pressure. Sharper bends may create excessive stress concentrations. Do not bend pipe until adhesive has cured. Method Pipe Property1 Units Value1 ASTM ATM2 Tensile strength Longitudinal 103 psi 35.0 D2105 161 MPa 241 Circumferential 103 psi 70.0 D1599 151 MPa 483 Tensile modulus Longitudinal 106 psi 3.0 D2105 161 GPa 20.7 Circumferential 106 psi 4.2 — — GPa 29.0 Compressive strength Longitudinal 103 psi 35.0 — 142 MPa 241 Compressive modulus Longitudinal 106 psi 3.0 — 142 GPa 20.7 Long-term hydrostatic design basis Static 103 psi 31.5 D2992(B) — MPa 217 Cyclic 103 psi 8.0 D2992(A) — MPa 55 Poisson’s ratio3 yx — 0.16 — — xy — 0.26 — — 1) Based on structural wall thickness. 2) Ameron test method. 3) The first subscript denotes the direction of contraction and the second that of the applied stress. x denotes longitudinal direction. y denotes circumferential direction. Typical mechanical properties of primary pipe Important Notice This literature and the information and recommendations it contains are based on data reasonably believed to be reliable. However, such factors as variations in environment, application or installation, changes in operating procedures, or extrapolation of data may cause different results. Ameron makes no representation or warranty, express or implied, including warranties of merchantability or fitness for purpose, as to the accuracy, adequacy or completeness of the recommendations or information contained herein. Ameron assumes no liability whatsoever in connection with this literature or the information or recommendations it contains. Product specifications are subject to change.
RkJQdWJsaXNoZXIy NDE1MjE4