Retail Petroleum Equipment
29 www.morbros.com AST S pill P revention E quipment 9095 A AST Overfill Prevention Valve Installed at the fill port of an aboveground storage tank. Used in a tight fill application, the valve terminates flow of product when the liquid level reaches a preset warning level (90-95% full). The valve is installed on a standard NPT male connection when used with the quick disconnect or female adaptor. When installed to manufacturers requirements, the OPV valve can help eliminate environmentally hazardous spills. All models are supplied with an adaptor to mount to Morrison Fig. 419 aluminum drop tubes. A test mechanism is also sold separately. The test mechanism allows a technician to pull on the test line at any time during the filling process to actuate the float and stop the fill. This allows a technician to verify the valve is working properly. ULC listed. Typical flow rate for 2" is 183 GPM at 10 PSI pressure drop. Typical flow rate for 3" is 566 GPM at 10 PSI pressure drop. Fig 9095A-AV … compatible with aviation fuel systems and the Morrison Fig. 539 Diffuser. Construction Details Adaptor…aluminum (hard-coat anodized) Female adaptor…ductile iron Body…anodized aluminum Plunger and dashpot…brass or nickel plated Shaft, linkages and hardware…stainless steel Piping…steel (epoxy coated) Features 1. Adjustable float (1½")…for setting the precise level of shutoff in the field and allowing it to be done using standard length pipe nipples. 2. Immediate and cushioned shutoff…full flow up to within 1-2 sec- onds of closing and no abrupt kickback or jolt, or startling noise in the line when valve closes. 3. One piece adaptor/coupler casting…no extra seams and joints to leak when top portion is under pressure from closing. 4. Dry disconnect…after shut off product is allowed to automatically drain from the highest point so fill nozzle can be removed without spilling. 5. Simple mechanics…minimum moving parts. Shutoff is activated by basic hydraulic principle with no springs, levers or complicated sequence leading to closure. Code Compliance NFPA 30, 30A, UFC, BOCA, SBCCI/SFC and PEI RP200. Florida DEP EQ 356. CARB VR 402A (some models). NOTE … For use on clean product only. Not suitable for motor oil. Size Maximum Pressure Maximum Viscosity 2" 100 PSI 150 Centistokes 3" 100 PSI 60 Centistokes Fig. 9095A Fig. 9095A-EVR Size Weight 2" valve w/2" male quick disconnect x 4" female threads* 14.1 lbs 2" valve w/2" female threads x 4" female threads 14.1 lbs 2" valve w/2" female threads x 4" female threads, EVR 14.1 lbs 2" valve w/2" male quick disconnect remote fill adaptor 12.6 lbs 2" valve w/3" male quick disconnect x 4" female threads 14.1 lbs 2" valve w/3" female threads x 4" female threads 14.1 lbs 2" valve w/3" female threads x 4" female threads, EVR 21.25 lbs 2" valve w/2" dry disconnect adaptor x 4" female thds, EVR 21.25 lbs 2" valve less top and upper pipe, EVR 14.1 lbs 3" valve w/3" male quick disconnect x 6" female threads* 29.0 lbs 3" valve w/3" female threads x 6" female threads 38.0 lbs 3" valve w/3" female threads x 6" female threads, EVR 38.0 lbs 3" valve w/3" male quick disconnect remote fill adaptor 26.0 lbs 3" valve less top and upper pipe, EVR 21.25 lbs * BSP Threads Available 9095 ATM Mechanical Test Device The 9095ATM Mechanical Test Mechanism allows a technician to pull the trip lever, activate the float and stop the fill at any time during the filling operation. The optional feature provides a simple verification the valve is operating properly. Available for non-EVR 2" or 3" models only.
Made with FlippingBook
RkJQdWJsaXNoZXIy NDU1Njc=