Retail Petroleum Equipment

Veeder-Root Sensor Application Guide 19 Direct Burial Cable The Veeder-Root direct burial cable system provides everything needed for an alternative wiring installation method for use with our probes and sensors. Installation of buried cable should only be done in those locations where existing conduit is not available, and where local codes permit the use of buried cable instead of conduit, and epoxy splices instead of junction boxes. Before considering buried cable runs, check with the local authority having jurisdiction to be sure that direct burial practices are acceptable at your location. If you are unfamiliar with direct burial techniques, you should consider either of two Veeder-Root kits: • Direct Burial Cable Site Preparation kit (P/N 848100-500) which contains the Direct Burial Installation Manual, a splice kit installation manual and the 890-SL joint sealant instruction guide. • Direct Burial Cable Site Demonstration kit (P/N 848100-502) which contains one splice kit with installation instructions, a 890-SL joint sealant instruction guide, a 6-inch piece of 2 conductor direct burial wire. After reviewing the contents of these kits, and after verifying local code requirements, you should be much more informed as to the applicability of this wiring method for your site. Direct Burial Cable Specifications Direct Burial Cable Components Order equal lengths of filler rod and either type cable. Refer to V-R manual 576013-858 to estimate length. • Filler rod - P/N 848100-1XX (lengths of 100 to 2000 feet, in increments of 100 feet) • Filler rod installation tool P/N 848100-904 (adjusts to 1/8”, 1/4”, 3/8”, or 1/2” saw cuts) • 2-conductor cable - P/N 848100-2XX (lengths of 100 to 2000 feet, in increments of 100 feet) • 3-conductor cable - P/N 848100-3XX (lengths of 100 to 2000 feet, in increments of 100 feet) • Cartridge of 890-SL sealant P/N 848100-800 (60 linear feet in 1/4” wide cut) • 4.5 gallon can of 890-SL sealant P/N 848100-805 (1200 linear feet in 1/4” wide cut) • Sealant cartridge gun, manual driven - P/N 8481021 (for use with P/N 848100-800 cartridge) • Sealant bulk gun, air driven - P/N 848100-903 (for use with P/N 848100-805 4.5 gallon can) 2 Conductor, Shielded Cable 3 Conductor, Shielded Cable Item Description Item Description Primaries Primaries Conductor #18 AWG (19/30) tinned copper Conductor #18 AWG (19/30) tinned copper Insulation Type Fluoropolymer Insulation Type Fluoropolymer Primary O.D. 0.063” nominal Primary O.D. 0.063” nominal Drain #20 AWG (7/28) tinned copper, located under the tape Drain #20 AWG (7/28) tinned copper, located under the tape Jacket Jacket Insulation type Fluoropolymer Insulation type Fluoropolymer Final O.D. 0.161” Final O.D. 0.171” Color Red tint Color blue tint UL temp rating 125°C UL temp rating 200°C

RkJQdWJsaXNoZXIy NDE1MjE4